Blue Selleckchem ML323 emission intensity leveled off kinetically at a certain point and decreased gradually (Figure 2). The turning point depended on the concentration of hypochlorite. Generally, higher concentrations of oxidants did not increase the maximum blue emission intensity
but just accelerated the transfer to the blue, leading to a fast response time towards the detection of oxidants. A trade-off between blue emitter stability and detection sensitivity suggested that the effective detection range was 1 to 120 μM for sodium hypochlorite [22]. One of the advantages of ratiometric Quisinostat detection is its tolerance to the variation in probe concentration. Usually, the emission intensity is proportional to the silver nanodot concentration. The higher the concentration, the stronger the emissions at 485 and 625 nm (Figure 4a,b). However, the I 485/I 625 ratios showed much less fluctuation at a given concentration of the oxidizing agent when the nanodot concentration varied between 15 and 35 μM (Figure 4c), indicating that the
silver nanodot concentration had little impact on the detection accuracy of the hypochlorite concentration. Figure 4 Emission and emission ratios of C24-Ag silver nanodots in the presence of 100 μM of sodium hypochlorite. Emission was examined after the addition of an oxidant to the nanodot solutions. The higher the concentration, the stronger the emissions at (a) 485 nm and (b) 625 nm. However, (c) the I 485/I 625 ratios at varied concentrations selleck kinase inhibitor showed much less fluctuation at a given concentration of the oxidizing agent. Since the intensity ratio of the blue/red strongly depends on reaction kinetics between silver nanodots and oxidants, some factors, such as pH and temperature, will influence the reaction rates. As we mentioned earlier, whether it is suitable as a probe in physiological
pH is an important factor in successfully measuring OCl− in bio-organisms. Our results (Figure 5) suggested that neutral solutions assisted consistent results. In this study, all the detections of oxidants were conducted in pH 7 solutions at 25°C, which are potentially useful for further in vivo probe designing. Figure 5 Influence of pH on oxidization and stability of C24-Ag Lepirudin silver nanodots in presence of 100 μM sodium hypochlorite. The emission intensity of 485 nm decreased at pH = 4 (a) but gradually increased at pH = 7 (b) and pH = 10 (c). The numbers before ‘hrs’ or ‘day’ in the legends indicate the time at which the emission was measured, and those after the ‘em’ indicate the excitation wavelengths. Sodium hypochlorite is used widely in some cleaners as a disinfectant and bleach. To accurately detect the hypochlorite concentration in household cleaners in vitro, we examined the influence of some salts and surfactants on the photoresponse of silver nanodots.